First, get the data about the pipeline, like flow direction, DN150 size, pressure, temperature, and water chemistry. This will help you to select a 6 Swing Check Valve for an industrial water pipeline. Then check that the seats, flanges, pressure class, and body material are all correct. Then consider the risk of water hammer, compare types of check valves, and make sure the supplier has test records and certificates. This guide was created for those who need to buy a reliable backflow prevention valve, such as plumbers, HVAC contractors, and distributors. You can write a complete specification, and you won't have to spend a lot of money on returns. Each part describes what it does.
| Model (DN) | Type | Material Options | Connection Type |
|---|---|---|---|
| DN50 | National Standard Medium Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN50 | National Standard Large Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN50 | National Standard Heavy Body (Thickened) | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN65 | National Standard Medium Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN65 | National Standard Large Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN65 | National Standard Heavy Body (Thickened) | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN80 | National Standard Medium Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN80 | National Standard Large Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN80 | National Standard Heavy Body (Thickened) | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN100 | National Standard Medium Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN100 | National Standard Large Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN100 | National Standard Heavy Body (Thickened) | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN125 | National Standard Medium Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN125 | National Standard Large Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN125 | National Standard Heavy Body (Thickened) | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN150 | National Standard Medium Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN150 | National Standard Large Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN150 | National Standard Heavy Body (Thickened) | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN200 | National Standard Medium Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN200 | National Standard Large Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN200 | National Standard Heavy Body (Thickened) | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN250 | National Standard Medium Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN250 | National Standard Large Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN250 | National Standard Heavy Body (Thickened) | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN300 | National Standard Medium Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN300 | National Standard Large Body | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
| DN300 | National Standard Heavy Body (Thickened) | Cast Iron / Stainless Steel / Carbon Steel | Flanged / Threaded |
Most of the time, a 6-inch valve fits DN150, but the pipe bore is not really 6 inches. The outside diameter of NPS 6 pipe is 6.625 inches (168.3 mm), and the inside diameter changes depending on the wall schedule. I never just order based on the nominal size. First, make sure you know the flow direction, installation position, flange size, and face-to-face length. Face-to-face dimensions for many types of valves are set by ASME B16.10. If the dimensions don't match, the pipe has to be cut on-site. Check to see if there is enough space around the valve. The disk needs to be able to fully open without touching the pipe wall.
The system gives you facts that help you make a good choice. Get the flow rate, the normal and maximum pressures, the temperature range, and the conditions under which the pump will shut down. Then write down the chemistry of the water, such as the chlorides, pH, treatment chemicals, and solids that are suspended in the water. Cold water, dirty water, and cleaned water all have different risks of corrosion and wear. Some metals and coatings can be damaged by water that has chloride in it, and sand and sediment wear down a seat over time. I think each line should have one data sheet. Contractors can then compare quotes on equal terms, and distributors can make sure they have the right body material in stock for each customer in their area.
Check the temperature and pressure at the same time, since the pressure that is allowed drops as the temperature rises. Under ASME B16.34, a Class 150 carbon steel valve can hold about 285 psig of pressure at room temperature. As the temperature rises, this pressure drops. It's important to choose a pressure class that is higher than both the normal working pressure and the maximum design pressure at the hot temperature of the machine. After that, look at the pressure drop, flow coefficient, and cracking pressure. These determine how much pump power the valve needs. Materials for the seat, gasket, coating, and bolts in hot water and HVAC loops must also be able to handle a wide range of temperatures.
The 6 Swing Check Valve can be bought from FLA in cast iron, carbon steel, or stainless steel. When it comes to general water duty, cast iron works well. When its coating stays on, carbon steel can handle more pressure, and you can find it a lot in fire protection and pipeline network lines. Stainless steel can handle chlorides and treated water that is acidic, so it can be used in coastal areas and chemical dosing lines. Check what your engineer's document says about what is needed for water. Some water specifications also call for ductile iron because it is strong against impact. Don't just look at how much the material costs; also look at the water chemistry, pressure, and how long you expect it to last.
The sealing performance of a 6 Swing Check Valve depends largely on its seat. In low-pressure water systems, resilient seats provide reliable sealing. Metal seats withstand higher temperatures and wear but may allow slight leakage under low differential pressure. Inspect the disk, hinge, shaft, spring, fasteners, and coating together, as one weak component can affect the entire valve. FLA's process includes casting, precision machining, assembly, and protective coating. Precisely machined sealing surfaces help prevent backflow. Since datasheets vary, ask the supplier which seat material is used in the quoted model. For critical projects, request material certificates so inspectors can trace each component back to its original specifications.
FLA has connections with flanges and threads. Most of the time, flanges are used on 6-inch lines because they make it easier to align, inspect, and replace a heavy valve. Before you place your order, make sure you know the flange diameter, pressure class, facing, drilling, and gasket type. Pressure-temperature ratings from ASME B16.34 are often used in U.S. projects. AWWA C508 is often used for swing-check valves in waterworks service, and MSS SP-71 is often used for gray iron swing check valves. Checking and testing valves is covered by API 598, so ask the supplier what process they use. So that the purchasing manager can check the product before it gets to the job site, ask for certified drawings, test records, and clear marking.
A swing check valve shuts off when the flow goes the other way. Flow slows down and turns around when a pump stops, pushing the disk onto the seat. If the disk closes late, the water starts moving backward first, and the sudden stop causes the pressure to rise. The pressure rise is equal to the fluid density times the wave speed times the change in velocity. This gives us an idea of how big that spike is. The risk is higher when there are long pipelines, fast speeds, and big changes in elevation. Also, look over the minimum flow speed again. If the flow is too slow, the disk can hit the stop and damage the hinge pin.
Changing the valves will not, by itself, eliminate water hammer. If your analysis indicates a high risk, a lever and weight, a spring to assist, or hydraulic damping could be added to the check valve. Air valves, hydropneumatic tanks, and variable-speed pump drives can also reduce transient pressure. For this line, a non-slam design may be better than a normal swing pattern. I think the contractor should let the supplier know the pump curve, the length of the pipe, and the shutdown conditions as soon as possible. Fire pumps require special attention when being worked on. NFPA 20 covers the installation of a stationary fire pump, so be sure the valve on the list will meet the needs of the project.
Swing check valves perform well on larger water lines with moderate flow rates, sufficient installation space, and the requirement for low pressure drop. This is because the open disk allows the flow to pass through easily. Design varies based on the circumstances. Lift check valves have tight control of the disk movement but have to be mounted in a certain orientation. Wafer and dual plate valves minimize face-to-face length and weight. This is helpful for sensitive pump systems. Silent check valves close fast and silently. Button check valves tend to be better suited to slurry and wastewater applications. Consider total cost, pressure drop, closing speed, solids-handling, footprint, and ease of maintenance before making your choice. No obvious winner in each line.
The valve to use depends on the machine’s usage and the kind of water used. Common uses include fire safety systems, pump outlets, pipeline networks, water treatment plants, HVAC systems, manufacturing facilities, public water systems, and irrigation networks, says FLA. FLA can also list fire protection lines with UL and FM if required. Wastewater lines carry fibers, sludge, and solids, so they need to be easy to inspect and not clog easily. Disks for coolant water lines and pump discharge lines must turn smoothly. If the service is marine or brackish, then chlorides, galvanic corrosion, coatings, and elastomers need to be looked at again. The valve is suitable for horizontal and vertical lines with flow upwards.
A clear checklist can help buyers who buy in bulk lower their risk. Before I approve an order, I need the following three types of information.
For a 6 Swing Check Valve, confirm the DN150 size, medium, flow rate, pressure, temperature, orientation, body material, seat type, coating, and connection type. Include the face-to-face dimension, pressure drop data, and cracking pressure so engineers can assess pump energy consumption and low-flow opening behavior. Record every value in the purchase request to avoid supplier assumptions.
Documentation: Obtain the datasheet, certified drawing, pressure-temperature chart, material certificates, test reports, and maintenance instructions. Make sure the ISO9001 and CE records are for the model you intend to purchase, and ask for UL and FM listings if the valve is being used in a fire protection line. File each record with the purchase order for future audits.
Commercial terms: Don’t just compare unit costs, but also lead time, packaging, customization possibilities, warranty terms, and export experience. Distributors need to check the SKU range and carton protection. Contractors need to check whether stock can handle continuous use on the project and replacement requirements. Plumbing and HVAC buyers should also verify dimensional accuracy prior to any bulk release.
Most ordering problems, like the wrong flange drilling, missing paperwork, and delays that stop a job, can be avoided with these checks.
FLA Industrial & Trading Co., Ltd. has been producing more than 1,000 kinds of hardware tools, Woodworking Clamps, electrical line tools, and malleable iron pipe fittings for about 40 years. The company operates in the US, Germany, and Australia and is trusted by people in the Fortune Global 500. Standard Products" target="_blank" style="color:blue" >products for the 6 Swing Check Valve are available from stock of 2,000 tons, and custom orders take 7 to 15 business days to complete. Our technical team supports 3D design and answers pricing or technical questions within 24-48 hours. All valves are pressure tested, leak tested, and functionally tested under an ISO 9001 quality system.
First, clean the pipe and get rid of any welding debris. One stray bead can get stuck in the disk. Check the body for a flow arrow and make sure the disk doesn't touch the pipe wall. If the manufacturer doesn't say otherwise, install on horizontal lines or vertical lines with upward flow. Before you tighten, make sure the flanges are lined up, and tighten the bolts in a cross pattern to keep the gasket load and pipe stress from being uneven. Watch out for leaks, noise, vibration, incomplete opening, and hard closing impacts while the system is being set up. Before the system starts to be used normally, these first checks find and fix most installation problems.
Develop a plan for regular inspections of the body, seat, disk, hinge, shaft, coating, and flange joints. Wastewater lines need to be inspected more frequently for sediment and debris. Monitor operating pressure, shutdowns, and repairs. If you see repeated reverse flow or water hammer, you should investigate immediately. Simple design with few moving parts results in low service costs and short downtime. Better to have spare gaskets and fasteners on hand than lose an hour in the fire pump room or during a plant shutdown. Distributors can keep the gaskets in stock that match the valves for returning customers.
If the water has a moderate amount of chemistry, pressure, or temperature, a resilient-seated cast iron or ductile iron valve is likely to be the best value for money. When there is more stress, heat, abrasion, or an aggressive chemical mix, carbon steel or stainless steel with better corrosion and inspection protection is recommended. If you need a non-slam closure, a small body, or a lower pressure drop, choose a different type of check valve. Ask for a project-specific engineering review for lines that are sensitive to pressure changes, long transmission lines, and pump discharge. If the items on your list don't fit a standard item, FLA can talk about non-standard sizes and configurations.
A 6 Swing Check Valve may not be suitable for a line with a 6-inch nominal diameter unless its actual dimensions and operating conditions match. Start by confirming the DN150 size, face-to-face length, pressure class at operating temperature, and water chemistry. Different pressure and corrosion conditions call for different materials, such as cast iron, carbon steel, or stainless steel. The seat type also affects sealing performance and wear. Flanged connections and standards such as ASME B16.34, AWWA C508, and MSS SP-71 help ensure fit and documentation. To reduce water hammer risk, consider how the pump stops, flow velocity, and pipe length. Some lines may be better suited to another check valve design. Proper installation, regular inspection, and complete records help keep the valve protected throughout its service life.
Yes, but only in a straight line with flow going up. This is because gravity pulls the disk together. The disk can stay open if flow goes down.
No, if the disk closes too late, a swing check valve can make water hammer worse. Lines with a lot of risk may need a lever and weight, hydraulic damping, air valves, or a design that doesn't slam.
FLA has valves in cast iron, carbon steel, and stainless steel. These valves can be connected to other parts through flanges or threads. Match the material to the water chemistry and pressure.
Products made by FLA are certified by both ISO9001 and CE. For fire safety purposes, UL and FM listings are available.
Send direction, flange standard, flow, pressure, temperature, water chemistry, and destination. FLA provides answers to questions about pricing and technical issues within 24 to 48 hours.
Need a reliable company that makes 6 Swing Check Valves? Cast iron, carbon steel, and stainless steel valves made by FLA Industrial & Trading Co., Ltd. are available. These valves are certified by ISO9001 and CE. We ship standard items right away, and custom orders take between 7 and 15 business days to finish. Send your data on flow, pressure, temperature, and flanges to sales@flaindustrial.com via email. For more information, go to flaindustry.com.
1. ASME B16.34 Valves—Flanged, Threaded, and Welding End, 2020
2. API Standard 598 Valve Inspection and Testing, 2016
3. AWWA C508 Swing-Check Valves for Waterworks Service, 2017
4. MSS SP-71 Gray Iron Swing Check Valves, Flanged and Threaded Ends, 2018
5. ASME B16.10 Face-to-Face and End-to-End Dimensions of Valves, 2017
6. NFPA 20 Standard for the Installation of Stationary Pumps for Fire Protection, 2022
YOU MAY LIKE